ARMAppender Syntax Description
appender class="ARMAppender" name="ARM"
specifies ARM as the
appender name. The ARMAppender name must be ARM.
Default |
None |
Restriction |
Only a single instance of an ARMAppender per process. |
Requirement |
Yes. ARM must be the name of the ARMAppender. |
name="Agent" value="
library-name"
specifies the name
of the library that contains the external ARM 4.0 agent library that
receives the events. See your vendor documentation for the correct
library name. Two values that can be used:
if no agent is specified,
output is sent to any referenced appenders. In the syntax example,
the output is sent to the file appender, "ARM-log-name".
specifies the name
of the library that contains the external ARM 4.0 agent library that
receives the events.
Default |
Output is sent to any referenced appenders |
Requirement |
No |
name="AppName" value="
application-name"
specifies the name
of the application. The maximum length of the value is 128 characters,
which includes the termination character ( / ). This value is sent
to the ARM_REGISTER_APPLICATION() function call. To override this
value, specify the SAS start-up option LOGAPPLNAME=application-name.
Default |
SAS |
Requirement |
No |
name="ConversionPattern" value="
conversion-pattern"
specifies how the log
event is written to the ARM log.
Default |
None. If a conversion pattern is not specified,
then the log event produces an empty string.
|
Requirement |
No |
name="Encoding" value="
encoding-value"
specifies the type
of character set encoding that is used for strings that are sent to
and calls that are received by the ARM 4.0 agent library.
Default |
Native Unicode character set for the host, or UTF-8
as required by the ARM 4.0 standards.
|
Requirement |
No |
name="File" value="
path-and-filename"
specifies the path
and filename of the file to which ARM messages are written.
Default |
None |
Requirement |
Yes |
name="GetTimes" value="TRUE | FALSE"
enables the ARM appender
to compute transaction response time metrics.
enables the appender
to compute transaction response times.
disables the appender
to compute transaction response times.
Default |
False |
Requirement |
No |
name="ManageCorrelators" value="TRUE | FALSE"
specifies whether ARMAppender
manages transaction correlation.
enables automatic transaction
correlation. The true value might affect existing benchmarks for ARM
2.0 records.
enables the application
to manage transaction correlation.
Default |
True |
Requirement |
No |
name="GroupName" value="
group-name"
specifies the name
of a group of application instances, if any. Application instances
that are started with a common run-time purpose are candidates for
using the same group name. The maximum length of the value is 256
characters. This value is passed to the ARM_START_APPLICATION() function
call.
Default |
Current user ID if available, otherwise NULL |
Requirement |
No |