Example 75.8 of Chapter 75: The POWER Procedure, demonstrates various ways you can modify and enhance plots created in the GLMPOWER or POWER procedures:
assigning analysis parameters to axes
fine-tuning a sample size axis
adding reference lines
linking plot features to analysis parameters
choosing key (legend) styles
modifying symbol locations
For example, replace the default PLOT statement with the following statement to modify the graphical results in Figure 18.2 to lower the minimum sample size to 60, show a reference line at power=0.9 with corresponding sample size values, distinguish standard deviation by color instead of panel, and swap the roles of and mean difference:
plot min=60 yopts=(ref=0.9 crossref=yes) vary(color by stddev, linestyle by meandiff, symbol by alpha);
Figure 18.3 shows the results. The plot reveals that only the scenarios with the largest mean difference and smallest standard deviation achieve a power of at least 0.9 for this sample size range.