The Power and Sample Size Application


A Simple Example

Suppose you want to determine the power for a new marketing study. You want to compare car sales in the southeastern region to the national average of 1.0 car per salesperson per day. You believe that the actual average for the region is 1.6 cars per salesperson per day. You want to test if the mean for a single group is larger than a specific value, so the one-sample t test is the appropriate analysis. The conjectured mean is 1.6 and the null mean is 1.0. You intend to use a significance level of 0.05 for the one-sided test. You want to calculate power for two standard deviations, 0.5 and 0.75, and two sample sizes, 10 and 20 dealerships.

First, open a new project by selecting FileNew on the menu bar or clicking the New icon on the toolbar. The New window appears. Then, select the appropriate analysis.

Figure 78.2: New Window

New Window


For this example, the selected analysis is the One-sample t test in the Means section, as shown at the top of Figure 78.2. Select the analysis from the list and click OK. The One-sample t test project window appears with the Edit Properties page displayed, as shown in Figure 78.3.

Figure 78.3: Edit Properties Page

Edit Properties Page


Enter a descriptive label of the project in the Project: field. For the example, change the description to Regional car sales versus the national average. The description is used to identify the project when you reopen it from the Open window.

Select FileSave to save the description change. Note in Figure 78.3 that the title bar of the window contains your project description after you have saved the change.

Properties of the project are displayed on several tabs. You can change from tab to tab by clicking a tab or by clicking the Next tab or Previous tab buttons. To display help about the properties for a tab, click the Help button at the bottom of the Edit Properties page.

Entering Parameter Values

First, click the Solve For tab and choose to calculate power or sample size. For this example, select the Power option, as shown in Figure 78.3.

Next, you must provide values for two analysis options and four parameters. These parameters are set in separate tabs on the Edit Properties page and are labeled Distribution, Hypothesis, Alpha, Mean, Standard Deviation, and Sample Size.

Distribution

Click the Distribution tab to select a Normal or Lognormal distribution. For the example, you are using means rather than mean ratios, so select Normal, as shown in Figure 78.4.

Figure 78.4: Distribution Tab

Distribution Tab


Hypothesis

Click the Hypothesis tab to select a one- or two-sided test. Because you are interested only in whether the southeastern region produces higher daily car sales than the national average, select One-sided test, as shown in Figure 78.5.

Figure 78.5: Hypothesis Tab

Hypothesis Tab


There are three one-sided test options: One-sided test, Upper one-sided test, and Lower one-sided test. The Upper one-sided test option would also be appropriate for this example.

Alpha

Click the Alpha tab to specify one or more significance levels. Enter 0.05, as shown in Figure 78.6.

Figure 78.6: Alpha Tab

Alpha Tab


This value will be the default unless the default has been changed in the Preferences window. To set preferences, select ToolsPreferences on the menu bar. For more information about setting preferences, see the section Setting Preferences.

Mean

Click the Means tab to enter one or more means and null means. For the example, enter 1.6 in the Mean table and 1.0 in the Null Mean table. Figure 78.7 shows the entered values.

Figure 78.7: Means Tab

Means Tab


Note that additional input rows are available if you want to enter additional sets of parameters. You can also append and delete rows using the  Fit Plot for Regression of Weight on Height and  Fit Plot for Regression of Weight on Height buttons beneath the table. In addition, by selecting a row and right-clicking, you can choose to insert and delete rows in the body of the table from a pop-up menu.

Standard Deviation

Click the Standard Deviation tab to enter standard deviations. You are interested in two standard deviations, 0.5 and 0.75. Enter them in the table, as shown in Figure 78.8.

Figure 78.8: Standard Deviation Tab

Standard Deviation Tab


Sample Size

You want to be able to sample between 10 and 20 dealerships. Click the Sample Size tab and enter these two values, as shown in Figure 78.9.

Figure 78.9: Sample Size Tab

Sample Size Tab


Scenarios

The input values are combined into one or more scenarios. In this case, each of the two standard deviations is combined with each of the two sample sizes for a total of four scenarios. Then power is computed for each scenario. In this example, only a single value or setting is present for the mean, null mean, and alpha level, so they are common to all scenarios.

Results Options

Click the Results tab to select results options including a Summary Table and a Power by Sample Size graph.

Figure 78.10: Results Tab

Results Tab


For this example, select both results check boxes: Create summary table and Create power by sample size graph, as shown in Figure 78.10. These selections can also be set as preferences; see the section Setting Preferences.

Customizing the Power by Sample Size Graph

Click the Customize button beside the Create power by sample size graph check box to customize the graph. The Customize Graph window contains two tabs: Axis Orientation and Value Ranges, as shown in Figure 78.11.

Figure 78.11: Customize Graph Window with Axis Orientation Tab

Customize Graph Window with Axis Orientation Tab


Click the Axis Orientation tab to select which quantity you would like to plot on the vertical axis. You can choose to display the quantity solved for (either power or sample size) on the vertical axis or you can choose to display power or sample size on the vertical axis with the other quantity appearing on the horizontal axis. The default is Quantity solved for (or power) on the vertical axis, which is appropriate for this graph.

The summary table is created using the two sample sizes specified in the Sample Size table, 10 and 20. If you want to create a graph that contains more than these two sample sizes, you can do so by customizing the value ranges for the graph. Click the Value Ranges tab to set the axis range for sample sizes, as shown in Figure 78.12.

Figure 78.12: Customize Graph Window with Value Ranges Tab

Customize Graph Window with Value Ranges Tab


Enter 5 for the minimum and 30 for the maximum. Also, select Interval between points in the drop-down list and enter a value of 1. These values set the sample size axis to range from 5 to 30 in increments of 1. The completed Value Ranges section of the window is shown in Figure 78.12.

When you solve for power, you can set a range for sample size values, but not for the powers; and vice versa when you solve for sample size. That is, you cannot set the range of axis values for the quantity that you are solving for.

Click OK to save the values that you have entered and return to the Edit Properties page.

Performing the Analysis

You have now specified all of the necessary input values. Click Calculate to perform the analysis, as shown in Figure 78.13.

Figure 78.13: Calculate Button on the Edit Properties Page

Calculate Button on the Edit Properties Page


Alternatively, you could choose to save the information that you have entered by selecting FileSave from the menu bar or clicking the Save toolbar icon, and perform the analysis at another time. No error checking is done when you save the project.

You can close the project by selecting FileClose on the menu bar or clicking the window close X in the upper right corner of the project window. You can reopen a project by selecting FileOpen on the menu bar or clicking the Open toolbar icon.

For this example, click Calculate.

Viewing the Results

Results appear on the View Results page and are viewable in separate tabs. The tabs include Summary Table, Graph, Narratives, SAS Log, and SAS Code (located on the left side of the View Results page). The Summary Table and Graph tabs appear if you selected those options on the Results tab of the Edit Properties page. The other tabs always appear.

Summary Table

Click the Summary Table tab to view the summary table.

Figure 78.14: Summary Table Tab with Fixed Scenario Elements and Computed Power Tables

Summary Table Tab with Fixed Scenario Elements and Computed Power Tables


The Summary table consists of two subtables, as shown in Figure 78.14. The Fixed Scenario Elements table includes the parameters or options that have a single value for the analysis. The Computed Power table contains the input parameters that have been given more than one value, and it shows the computed quantity, power.

Thus, the Computed Power table contains four rows for the four combinations of standard deviation and sample size. From the table you can see that all four powers are high. The smallest value of power, 0.754, is associated with the largest standard deviation and the smallest sample size. In other words, the probability of rejecting the null hypothesis is greater than 75% in all four scenarios.

Power by Sample Size Graph

Click the Graph tab to view the power by sample size graph.

The power by sample size graph in Figure 78.15 contains one curve for each standard deviation. For a standard deviation of 0.5 (the upper curve), increasing sample size above 10 does not lead to much increase in power. If you are satisfied with a power of 0.75 or greater, 10 samples would be adequate for standard deviations between 0.5 and 0.75.

Figure 78.15: Graph Tab with Power by Sample Size Graph

Graph Tab with Power by Sample Size Graph


Narratives

Click the Narratives tab to display a facility for creating narratives.

Narratives are descriptions of the values that compose each scenario and include a statement about the computed power or sample size.

To create narratives, choose one or more scenarios in the table at the bottom of the tab. A narrative for each selected scenario is displayed in the top portion of the tab. See Figure 78.16.

Figure 78.16: Narrative Tab

Narrative Tab


For the example, select the first row in the table. The following narrative is displayed for the scenario with a standard deviation of 0.5 and a sample size of 10:

For a one-sample t test of a normal mean with a one-sided significance level of 0.05 and null mean 1, assuming a standard deviation of 0.5, a sample size of 10 has a power of 0.967 to detect a mean of 1.6.

You can select several rows in the table. As you select each one, a corresponding narrative is created and displayed in the top portion of the table. Selecting a second scenario (the third row) produces the following output, where the narrative for the first row is followed by the narrative for the third row:

For a one-sample t test of a normal mean with a one-sided significance level of 0.05 and null mean 1, assuming a standard deviation of 0.5, a sample size of 10 has a power of 0.967 to detect a mean of 1.6. For a one-sample t test of a normal mean with a one-sided significance level of 0.05 and null mean 1, assuming a standard deviation of 0.75, a sample size of 10 has a power of 0.754 to detect a mean of 1.6.

Other Results

Other results include the SAS log and the SAS code.

The SAS log that was produced when the Calculate button was last clicked appears on the SAS Log tab.

The SAS statements that produced the results appear on the SAS Code tab.

Printing Results

To print one or more results, select FilePrint from the menu bar or click the Print toolbar icon. A window is displayed that lists all available results, as shown in Figure 78.17. Select the results that you want to print and click OK.

Figure 78.17: Print Selection Window

Print Selection Window


Changing Properties

If you want to change some values of the properties and rerun the analysis, change to the Edit Properties page and continue. The icons for selecting the Edit Properties and View Results pages are in the command bar just below the project window title.

Closing the Project

When you are finished working with a project, close it by clicking the X in the upper right corner of the project window or selecting FileClose on the menu bar. If you have not saved the project, you will be asked if you want to save it before closing.

Opening a Project

You can reopen existing projects using the Open window. Select FileOpen on the menu bar or click the Open toolbar icon.

Figure 78.18: Open Window Containing the Analysis Created in the Example

Open Window Containing the Analysis Created in the Example


As shown in Figure 78.18, the analysis that you just completed is listed in the table. The label that you assigned to it, Regional car sales versus the national average, appears in the Project column of the table. The table also contains the date that the analysis was last modified. If you do not see the project that you are looking for, change the value of the Display projects by date box to All by selecting All from the drop-down list, and click the Change display button.

You can sort the projects in the table by clicking the header of the desired column. The sort direction is indicated by arrows displayed in the column header.

Select the project that you want to open and click OK. You can also double-click the project entry to open it.

Changing Values and Rerunning the Analysis

After viewing the graph, you might want to re-create the graph with a different range for sample sizes. On the Results tab of the Edit Properties page, click the Customize button for the power by sample size graph. The Customize Graph window is displayed.

On the Value Ranges tab of the window, change the Maximum value in the Sample Size table from 30 to 20. Click OK.

Rerun the analysis by clicking Calculate. The View Results page is displayed again and the graph now has the new maximum value for the sample size axis.