The following notation is used in this section:
|
process mean (expected value of the population of measurements) |
|
process standard deviation (standard deviation of the population of measurements) |
|
mean of measurements in ith subgroup |
|
range of measurements in ith subgroup |
|
sample size of ith subgroup |
N |
number of subgroups |
|
weighted average of subgroup means |
|
100pth percentile of the standard normal distribution |
Each point on an chart indicates the value of a subgroup mean (
). For example, if the tenth subgroup contains the values 12, 15, 19, 16, and 14, the value plotted for this subgroup is
![]() |
By default, the central line on an chart indicates an estimate for
, which is computed as
![]() |
If you specify a known value () for
, the central line indicates the value of
.
You can compute the limits in the following ways:
as a specified multiple (k) of the standard error of above and below the central line. The default limits are computed with k = 3 (these are referred to as
limits).
as probability limits defined in terms of , a specified probability that
exceeds the limits
The following table provides the formulas for the limits:
Table 17.66: Limits for
Charts
Control Limits |
---|
LCL = lower limit = |
UCL = upper limit = |
Probability Limits |
---|
LCL = lower limit = |
UCL = upper limit = |
Note that the limits vary with . If standard values
and
are available for
and
, respectively, replace
with
and
with
in Table 17.66.
You can specify parameters for the limits as follows:
Specify k with the SIGMAS= option or with the variable _SIGMAS_
in a LIMITS= data set.
Specify with the ALPHA= option or with the variable
_ALPHA_
in a LIMITS= data set.
Specify a constant nominal sample size for the control limits with the LIMITN= option or with the variable
_LIMITN_
in a LIMITS= data set.
Specify with the MU0= option or with the variable
_MEAN_
in a LIMITS= data set.
Specify with the SIGMA0= option or with the variable
_STDDEV_
in a LIMITS= data set.