This example illustrates probability plotting and distribution fitting for data grouped by the levels of a special group-variable. The data are from an accelerated life test of an insulating fluid and are the times to electrical breakdown of the fluid under different high voltage levels. Each voltage level defines a subset of data for which a separate analysis and Weibull plot are produced. These data are the 26kV, 30kV, 34kV, and 38kV groups of the data provided by Nelson (1990, p. 129). The following statements create a SAS data set containing the lifetimes and voltages:
data fluid; input Time voltage $ @@; datalines; 5.79 26kv 1579.52 26kv 2323.7 26kv 7.74 30kv 17.05 30kv 20.46 30kv 21.02 30kv 22.66 30kv 43.4 30kv 47.3 30kv 139.07 30kv 144.12 30kv 175.88 30kv 194.90 30kv 0.19 34kv .78 34kv 0.96 34kv 1.31 34kv 2.78 34kv 3.16 34kv 4.15 34kv 4.67 34kv 4.85 34kv 6.50 34kv 7.35 34kv 8.01 34kv 8.27 34kv 12.06 34kv 31.75 34kv 32.52 34kv 33.91 34kv 36.71 34kv 72.89 34kv .09 38kv 0.39 38kv .47 38kv 0.73 38kv .74 38kv 1.13 38kv 1.40 38kv 2.38 38kv ;
The variable Time
provides the time to breakdown in minutes, and the variable Voltage
provides the voltage level at which the test was conducted. These data are not censored.
The RELIABILITY procedure plots the data for the different voltage levels on the same Weibull probability plot, fits a separate distribution to the data at each voltage level, and superimposes distribution lines on the plot.
The following statements produce the probability plot shown in Figure 16.5 for the variable Time
at each level of the group-variable Voltage
:
proc reliability data=fluid; distribution Weibull; pplot time=voltage / overlay noconf; run;
The input data set FLUID is specified by the DATA= option in the PROC RELIABILITY statement. The PROBPLOT statement option OVERLAY specifies that plots for the groups are to be overlaid rather than displayed separately. The option NOCONF specifies that no confidence bands are to be plotted, since these can interfere with one another on overlaid plots; confidence bands are displayed by default.
A summary table that contains information for all groups is displayed. In addition, information identical to that shown in Figure 16.3 is tabulated for each level of voltage. The summary table for all groups and the tables for the 26kV group are shown in Figure 16.6 and Figure 16.7.
Figure 16.7: Partial Listing of the Tabular Output for the Insulating Fluid Data
Weibull Parameter Estimates | |||||
---|---|---|---|---|---|
Parameter | Estimate | Standard Error |
Asymptotic Normal | Group | |
95% Confidence Limits | |||||
Lower | Upper | ||||
EV Location | 6.8625 | 1.1040 | 4.6986 | 9.0264 | 26kv |
EV Scale | 1.8342 | 0.9611 | 0.6568 | 5.1226 | 26kv |
Weibull Scale | 955.7467 | 1055.1862 | 109.7941 | 8319.6794 | 26kv |
Weibull Shape | 0.5452 | 0.2857 | 0.1952 | 1.5226 | 26kv |
Weibull Percentile Estimates | |||||
---|---|---|---|---|---|
Percent | Estimate | Standard Error |
Asymptotic Normal | Group | |
95% Confidence Limits | |||||
Lower | Upper | ||||
0.1 | 0.00300636 | 0.02113841 | 3.11203E-9 | 2904.27046 | 26kv |
0.2 | 0.01072998 | 0.06838144 | 4.03597E-8 | 2852.65767 | 26kv |
0.5 | 0.0577713 | 0.31803193 | 1.19079E-6 | 2802.78862 | 26kv |
1 | 0.20695478 | 1.00385021 | 0.00001538 | 2784.16263 | 26kv |
2 | 0.74484901 | 3.12705686 | 0.00019885 | 2790.0941 | 26kv |
5 | 4.1142692 | 13.7388263 | 0.00591379 | 2862.3304 | 26kv |
10 | 15.406565 | 41.4763373 | 0.07873508 | 3014.69497 | 26kv |
20 | 61.0231127 | 125.020566 | 1.10053199 | 3383.65475 | 26kv |
30 | 144.246801 | 242.203982 | 5.36856883 | 3875.73303 | 26kv |
40 | 278.770459 | 398.048692 | 16.9761581 | 4577.77125 | 26kv |
50 | 487.954708 | 610.02855 | 42.0948552 | 5656.26835 | 26kv |
60 | 814.147288 | 920.537706 | 88.770543 | 7466.84412 | 26kv |
70 | 1343.42243 | 1433.97868 | 165.818889 | 10884.0666 | 26kv |
80 | 2287.87124 | 2445.52431 | 281.5628 | 18590.3635 | 26kv |
90 | 4412.96962 | 5148.34986 | 448.419608 | 43428.7452 | 26kv |
95 | 7150.89745 | 9248.2654 | 566.892142 | 90202.9338 | 26kv |
99 | 15735.8513 | 24666.0388 | 728.831025 | 339745.437 | 26kv |
99.9 | 33104.172 | 62018.1074 | 841.826189 | 1301796.28 | 26kv |